<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Heart pearls! &#187; pacemaker</title>
	<atom:link href="http://www.heartpearls.com/tag/pacemaker/feed" rel="self" type="application/rss+xml" />
	<link>http://www.heartpearls.com</link>
	<description>For all cardiology enthusiasts! Bonjour! Click on the title above to go to site index so that you can browse the articles!</description>
	<lastBuildDate>Sun, 18 Jul 2010 07:59:48 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.8.4</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>Cardiac pacemakers</title>
		<link>http://www.heartpearls.com/2009/05/cardiac-pacemakers.html</link>
		<comments>http://www.heartpearls.com/2009/05/cardiac-pacemakers.html#comments</comments>
		<pubDate>Sun, 10 May 2009 02:25:37 +0000</pubDate>
		<dc:creator>Dr Jayachandran Thejus MD</dc:creator>
				<category><![CDATA[Arrhythmias]]></category>
		<category><![CDATA[pacemaker]]></category>

		<guid isPermaLink="false">http://www.heartpearls.com/?p=130</guid>
		<description><![CDATA[Cardiac pacemakers
 
Pacemaker nomenclature
The code for pacemaker is called NASPE/BPEG code. These stand for North American Society of Pacing and Electrophysiology and British Pacing and Electrophysiology Group. The first code was in 1974. Present code was made in 2002. Positions are in the order- chamber paced, chamber sensed, response to sensing, rate modulation and multisite pacing. [...]]]></description>
			<content:encoded><![CDATA[<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Cardiac pacemakers</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;"> </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;"><strong>Pacemaker nomenclature</strong></span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">The code for pacemaker is called NASPE/BPEG code. These stand for North American Society of Pacing and Electrophysiology and British Pacing and Electrophysiology Group. The first code was in 1974. Present code was made in 2002. Positions are in the order- chamber paced, chamber sensed, response to sensing, rate modulation and multisite pacing. For 1,2 and 5, codes may be OAVD- none, atrial, ventricular and dual. For 3, code may be OTID- none, triggered, inhibited or dual. For 4, OR- none or rate modulation present.</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;"> </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;"><strong>Indications for permanent pacing (PP) </strong></span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Commonest indication for PP is sinus node disease, second commonest being AV node disease.</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">For complete heart block, PP is always indicated. There is some confusion about congenital CHB, with some experts of the opinion that PP is indicated here only if there is (CBSEE)</span></p>
<ul>
<li>
<div class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Congestive heart failure</span></div>
</li>
<li>
<div class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Bradycardia of less than 50 when awake</span></div>
</li>
<li>
<div class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Syncope or presyncope</span></div>
</li>
<li>
<div class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Ectopy from ventricles or</span></div>
</li>
<li>
<div class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Exercise intolerance.</span></div>
</li>
</ul>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;"> </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">If second degree heart block is symptomatic, PP is indicated. If asymptomatic, PP is indicated if</span></p>
<ul>
<li>
<div class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Asystole &gt; 3 sec when awake</span></div>
</li>
<li>
<div class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Rate &lt; 40 when awake</span></div>
</li>
</ul>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">And may be indicated if</span></p>
<ul>
<li>
<div class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Due to neuromuscular disorder</span></div>
</li>
<li>
<div class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Intra or infra Hisian block (not for supra Hisian).</span></div>
</li>
</ul>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;"> </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">For bi or tri fascicular block, PP is indicated if there is transient CHB and PP may be indicated if symptomatic.</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;"> </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">For sinus node dysfunction, PP is indicated if symptomatic and is not indicated if asymptomatic. For reversible causes like Lyme disease, PP is naturally not indicated.</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;"> </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">For neurocardiogenic syncope (VVS &amp; carotid sinus hypersensitivity), if the predominant cause is cardioinhibitory rather than vasodepressor (this can be made more clear by tilt table testing), PP is indicated if drugs such as beta blockers are ineffective. Dual chamber pacing was found to be useful in this setting in some studies (VPS-I and VASIS) but not in others (VPS-II).</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;"> </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Pacing for the prevention of tachyarrhythmias- PP is indicated in pause-dependent VT and PP may be indicated for congenital long QT syndrome. </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;"> </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;">Pacing to prevent atrial fibrillation (AF)- Atrial pacing has been studied for prevention of AF. The concept is that it decreases the refractoriness of dispersion in the atrium. Various techniques are used. Usual single site atrial pacing, strial septal pacing and Bachmann’s bundle pacing are single site pacing techniques. Dual site pacing is with one lead in usual RA position and other lead in the coronary sinus. Many pacing algorithms have been developed too. Prevention of AF by pacing was shown in ADOPT trial, but was not shown in the ASPECT trial.</p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;">Cardiac resynchronization therapy- CRT is a technique to reestablish synchronous contraction between LV free wall and IVS. Usually, biventricular pacing is needed, but LV pacing alone can achieve this in some persons. Trials have shown that this improves functional status, but not longevity. The indication for CRT is if all of the following are met-</p>
<ul>
<li>
<div class="MsoNormal" style="margin: 0in 0in 0pt;">NYHA III or IV</div>
</li>
<li>
<div class="MsoNormal" style="margin: 0in 0in 0pt;">Optimized medical therapy</div>
</li>
<li>
<div class="MsoNormal" style="margin: 0in 0in 0pt;">LVEF 0.35</div>
</li>
<li>
<div class="MsoNormal" style="margin: 0in 0in 0pt;">NSR</div>
</li>
<li>
<div class="MsoNormal" style="margin: 0in 0in 0pt;">QRS more than 120 msec</div>
</li>
</ul>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: 12pt; font-family: &quot;Times New Roman&quot;; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;">PP in HCM- Dual chamber PP for HCM has not been shown to improve symptoms, though it does decrease the LVOT gradient, presumably due to RV apical pacing causing altered septal activation leading to less LVOT narrowing and hence less Venturi effect causing less SAM. So, it is only a IIb indication.</span></p>
<div></div>
<p><span style="font-size: 12pt; font-family: &quot;Times New Roman&quot;; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;"></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><strong>Selection of appropriate pacing mode</strong></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;">For patients with sinus node dysfunction AAI is preferred to VVI due to definite morbidity benefit (thromboembolism, AF, HF) and controversial mortality benefit. (The main studies are MOST and Andersen et al.)</p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;">For heart blocks, DDD does not offer benefit over VVI (UKPACE study).</p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;">Along with an ICD, when antibradycardia pacing is not needed, VVI is better than DDD (DAVID study)!</p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><strong>Modes and timing cycles</strong></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;">VVI- after a ventricular event, the pacemaker delivers a ventricular spike only after waiting for a time interval called lower rate interval. If a ventricular activity occurs within this time, the LR timer is reset, but activity in an initial part of the LRI called the ventricular refractory period (VRP) will not reset the LR timer.</p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;">AAI- Like for VVI, there is a LR interval and an atrial refractory period. Before implanting an AAI for a sinus node disease, we have to be sure of good AV nodal conduction by demonstrating 1:1 conduction of atrial beats at a rate of 140/mt.</p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;">DDI- This is like a combination of AAI and VVI, but there is not VAT function, presence of which would have made it a DDD. VAT function (or tracking of P) refers to pacing of ventricle after a P wave if there is AV conduction (after waiting for an interval called the AVI or AV interval) to produce an intrinsic QRS. DDI is usually a programmable option in DDD pacemakers and is switched on if atrial tachyarrhythmias are causing problems.</p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;">VDD- This is used for heart blocks. Its advantage is use of a single lead only- the atrial sensor is at the atrial position of the ventricular lead. It essentially functions as a VVI, with the additional option of P tracking- that is, if an intrinsic P occurs, the ventricular lead will wait for AVI and will pace only if the P is not conducted to produe a QRS (if a P conducts in spite of the heart block, it is allowed to work!).</p>
<p> </p>
<p> </p>
<p> </p>
<p></span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> DDD- In addition to the settings for VDD, there is a new setting to decide when atrial pacing should start if there is no atrial activity. After ventricular activity, if there is no atrial activity at the end of an interval called the VA interval, an atrial pacing spike is given. But, as for the VRP of VVI, there is an interval after the QRS when atrial activity is not sensed by the atrial sensor- this is called PVARP or post ventricular atrial refractory period. Since the atrial sensor is also not allowed to sense during the entire AVI, AVI + PVARP constitutes total atrial refractory period or TARP. The need for a PVARP is to avoid a retrograde P from being sensed and initiate an AVI, this again producing a retrograde P which is again sensed- thus causing an endless loop or pacemaker mediated tachycardia. If still this is occurring, just increase the PVARP so that the retrograde P would not be sensed.</p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> DDD is especially useful for AV block (even though, as told earlier, no benefit over VVI was shown in studies). DDD is not useful in SSS and AF.</p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;">DDD can manifest as</p>
<ul>
<li>
<div class="MsoNormal" style="margin: 0in 0in 0pt;">NSR,</div>
</li>
<li>
<div class="MsoNormal" style="margin: 0in 0in 0pt;">atrial pacing if no atrial activity and normal AV conduction,</div>
</li>
<li>
<div class="MsoNormal" style="margin: 0in 0in 0pt;">P synchronous pacing if normal atrial activity and no AV conduction and</div>
</li>
<li>
<div class="MsoNormal" style="margin: 0in 0in 0pt;">AV sequential pacing if no atrial activity and no AV conduction.</div>
</li>
</ul>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> Rate adaptive pacing- The sensors usually measure activity, minute ventilation or QT. Activity sensors are most commonly used and may be accelerometers or piezoelectric crystals, the former being more physiological.</p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;">Nowadays DDDR is most commonly used. These can be reprogrammed to AAIR in cases of sinus node dysfunction only. VVIR is used instead of DDDR in patients with AF.</p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;">VVI is contraindicated if it causes hypotension or VA conduction.</p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: 12pt; font-family: &quot;Times New Roman&quot;; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;">Pacemakers are implanted epicardially if there is no access to the right ventricle or if there is an intracardiac shunt that could predispose to thromboembolism. A lateral subclavian approach is preferred to medial to avoid crush injury to lead and pneumothorax. </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><strong>Pacemaker programming</strong></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;">Pulse width- usually triple the threshold is used.</p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;">Voltage- usually double the threshold is used.</p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;">Microjoules- not usually done- if done, usually triple the threshold is used.</p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;">Mode switching- If a rapid atrial rhythm occurs in a PP capable of P tracking (DDD or VDD), to avoid rapid ventricular rhythm the PP automatically switches off P tracking- that is, in effect it becomes DDI or VVI (note that if DDD/VDD – VAT = DDI/VVI).</p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;">AVI- is programmed in such a way as to support intrinsic AV conduction.</p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;"><strong>Pacemaker complications</strong></span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">During implantation, complications like pneumothorax, hemothorax, arterial puncture, AV fistula, thoracic duct injury and brachial plexus injury can occur. </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">For hematoma, aspiration is not advised. Evacuation is done only if absolutely necessary.</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Lead entry into the LV, via a PFO, is recognized by posterior position on lateral view and by RBBB pacing pattern. It can cause embolization.</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Lead perforation may manifest as cardiac tamponade, pericardial effusion, pericarditis, friction rub, increased threshold, RBBB pacing pattern or intercostal muscle or diaphragmatic contraction. Withdraw lead and reposition.</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Subclavian vein thrombosis is usually asymptomatic.</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Lead dislodgement may be macro or micro, former being visible radiographically. </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Loose connector pin can cause loss of output. </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Insulation break can cause sensing or pacing problems. </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Lead fracture can occur, especially at the costoclavicular space.</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">VPCs can occur in the first two days of pacemaker implantation due to mechanical stimulation. They have the same configuration as the pacemaker induced complex. They resolve.</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Diaphragmatic stimulation may be due to direct stimulation, when the left hemidiaphragm is paced, or due to phrenic nerve stimulation, when the right hemidiaphragm is paced. Try decreasing voltage or pulse width. If that does not work, reposition.</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Pacemaker infection is usually local rather than septicemic. Early infection is caused by Staph aureus and is aggressive while late infection is caused by Staph epidermidis and is usually indolent. Local antibiotic irrigation helps to prevent infection. Treatment is removal of the entire system including leads.</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Pacemaker erosion may be due to infection or a tight pocket. Treatment is removal of the system. The same system cannot be reimplanted at another site- a new one has to be used. So impending erosion is an emergency- revise the pocket and reimplant.</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;"> </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Troubleshooting</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Failure to capture- Means a pacing artifact is present without depolarization. Causes are high threshold, lead fracture, insulation break, lead dislodgement, lead perforation, impending battery depletion, functional noncapture, and high threshold due to drugs or metabolic problems. Functional noncapture refers to failure to capture due to pacing spike falling in refractory period of a beat. </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Failure to output- Means that there is no pacing artifact. Causes are oversensing, battery depletion, loose set screw, lead fracture, internal insulation failure in a bipolar lead and air in the pocket of a unipolar pacemaker.</span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">True undersensing occurs due to lead dislodgement, lead fracture or battery depletion. Functional undersensing occurs when a cardiac activity falls within a programmed refractory period of the pacemaker. </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"><span style="font-size: small; font-family: Times New Roman;">Fusion beat is a hybrid of intrinsic and pacemaker induced activities. Pseudofusion beat is due to pacemaker spike falling on intrinsic activation, without pacemaker induced activation. It occurs in two situations- when pacing rate and intrinsic rate are similar and when there is an intraventricular conduction defect. In the former situation, it occurs because the initial part of the intrinsic activation is not sensed by the pacemaker and hence it discharges. </span></p>
<p class="MsoNormal" style="margin: 0in 0in 0pt;"> </p>
]]></content:encoded>
			<wfw:commentRss>http://www.heartpearls.com/2009/05/cardiac-pacemakers.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
